“The heat’s running, but it’s 61 in here and the air coming out feels lukewarm.” That’s how a lot of winter mornings start for us. The night before dropped into the mid-twenties across Haskell County, and somewhere outside Stigler, on a few acres down a gravel road, a family woke up to a house that wouldn’t warm up. Below is what a no-heat call like that usually looks like from start to finish, so you know what to check before you call and what happens once we’re in your driveway.
This is a composite of the kind of calls we run every winter, not one particular customer, but every step in it is real.
The Call Comes In
The home is a manufactured home with a heat pump outside and an electric air handler in a hall closet, which is a setup we see all over the country roads around Stigler. The thermostat says “Aux Heat,” the vents are blowing air that’s barely warm, and the house has been losing ground since about 3 AM.
On the phone we ask a few quick questions. What does the thermostat say? Is the outdoor unit running? Do you hear a fan outside? Have you checked the breakers? Is anything iced over? Those answers help us know which parts to have on the truck. Because this call came in before office hours, we also tell the homeowner up front that early-morning and after-hours calls are billed at an overtime rate, and we quote that rate before we head out. Then they decide.
First Look: Thermostat and Breaker Panel
We start inside, because the simple stuff gets ruled out first. The thermostat is set to heat, the batteries are good, and the setting is where it should be. Then the breaker panel. The air handler’s heat strips run on their own breakers, separate from the outdoor unit. In this house, one of the two heat strip breakers has tripped. That explains why the backup heat is only putting out about half of what it should.
A tripped breaker always gets a “why” before it gets reset. Breakers trip for a reason, and flipping one back on without looking is how small electrical problems turn into burned wires.
Outside at the Heat Pump
Out at the heat pump, the outdoor fan isn’t spinning and the compressor isn’t running, even though the thermostat is calling for heat. There’s frost on the coil but no solid ice. We shut the power off at the disconnect, pull the access panel, and find the problem fast: the run capacitor is swollen on top. A capacitor gives the compressor and fan motor the push they need to start. When it fails, neither one can get going, and the whole job of heating the house falls on the backup heat strips.
🛠 What we do: we test the capacitor with a meter rather than going by looks alone, then check the contactor, the wiring, and both motors to make sure the capacitor was the cause and not the result of something else, like a motor that’s dragging.
Inside at the Air Handler
With the outdoor unit down, the heat strips had been running nonstop all night. Running that hard, a loose wire connection at one of the strip terminals had heated up until its breaker tripped. That’s the second half of the story, and it’s why the house couldn’t keep up even on backup heat.
We tighten and clean that connection, replace a terminal that’s discolored from heat, and check the amp draw on each heat strip so we know they’re all pulling what they should. We also pull the filter, which is overdue, and swap it.
The Fix and the Test
The new capacitor goes in, the outdoor unit starts, and the fan spins up. We watch the system run a full heating cycle and check the air temperature coming out of the vents against the air going in, so we know the heat pump is really heating and not just running. Then we force a defrost cycle to make sure the heat pump clears its own frost, and confirm the backup heat comes on during defrost.
🛠 What we do: before we leave, we walk the homeowner through what failed and why, show them the old capacitor, and point out where the heat strip breakers are in the panel. The house is climbing back toward the setpoint, and with the heat pump carrying the load again, the electric bill will drop back down too.
What You Can Check Before You Call
You can rule out a lot in five minutes. Make sure the thermostat is set to heat and has fresh batteries. Check the breaker panel for anything tripped, but if a breaker trips again after one reset, leave it off and call. Go outside and see whether the outdoor fan is turning. Look for solid ice on the coil. Pull the filter and replace it if it’s dirty.
If the outdoor unit isn’t running, set the thermostat to emergency heat so the backup carries the house, and call us.
Do I need to worry if my thermostat says “Aux Heat”?
Not by itself. Aux heat coming on during defrost or on a very cold night is normal. Aux heat that stays on all the time, or a house that won’t warm up even with it on, means the heat pump probably isn’t doing its share.
Do I need a new heat pump if it stops running?
Usually not. A capacitor, contactor, or fan motor is a common repair, and those are far more likely than a failed compressor. We’ll tell you which it is before anything gets replaced.
Heating Repair for Stigler and Haskell County
Clark HVAC is a family-owned, licensed and insured heating and cooling company, and we repair heat pumps, electric air handlers, and gas and propane furnaces in Stigler and the surrounding towns. Whether you’re in town or out at the end of a long gravel drive, if your house won’t warm up, call us. We’ll find the cause, explain it in plain English, and quote the repair before we start.